RF 96 ST SW922 Vcc extern

Features/Options

  • Thermoplastic enclosure
  • Mounting details to EN 50047
  • sWave® wireless technology
  • Plug-in connector M12
  • Connection: for the use with wireless sensors, series RF, 3-wire PNP sensors 24 VDC and/or external NO contacts with gold contacts
  • Power supply: 24 VDC
  • Easy programming of receiver
  • Output signal can be individually configurated at the receiver

Technical data

StandardsEN 60947-5-1; EN 61000-6-2, -3,
EN 61000-4-2, -20, -4, -5, -6;
EN 301 489-1; EN 301 489-3;
EN 300 220-1; EN 300 220-2
Enclosureglass-fibre reinforced, shock-proof thermoplastic (PA 66), self-extinguishing UL 94-V0
ConnectionPlug-in connector M12 x 1, 4-pole
Degree of protectionIP 67 to IEC/EN 60529
ProtocolsWave®
Ambient temperature–20 °C … +65 °C
Operation cyclesmax. 1440 telegrams/h
Switching frequencymax. 5 Hz
Rated operating voltage range UB10 - 30 VDC Pin 1 and Pin 3
Rated operating isolation voltage Ui75 VDC
Uimp500 V
Rated operating current Ie2.5 mA
Standby current15 µA
Voltage drop Ue Ua–1.5 V
Max. load current100 mA
Switching point E1 E2> 5 VDC
Frequency916.5 MHz (Japan)
Transmission power< 1 mW
Data rate66 kbps
Channel bandwidth400 kHz
Sensing rangemax. 150 m outside,
max. 20 m inside
Actuating timemin. 80 ms
Approvals Japan: ARIB STD-T108: 204-610002
Ordering details
Type   Material no.